Vapour Retarder (Vapour Control Layer)

Also known as vapour control layer · VCL · vapor barrier · vapour barrier · air barrier

A layer placed on the warm side of roof insulation to limit water vapour moving from the building into the roof, where it could condense.

1 min read4 sourcesGlobal
Cite this entry"Vapour Retarder (Vapour Control Layer)." roof.wiki. https://roof.wiki/vapor-retarder/ (accessed 2026-11-02).
Class I permeance
0.1 US perm or less
UK term
Vapour control layer (VCL)
UK condensation standard
BS 5250 (referenced by BS 6229)
Placement (cold climate)
Warm side of insulation

Quick answers

What is Vapour Retarder (Vapour Control Layer)?
A layer placed on the warm side of roof insulation to limit water vapour moving from the building into the roof, where it could condense.
Which standards apply to Vapour Retarder (Vapour Control Layer)?
BS 5250 (referenced by BS 6229)

A vapour retarder, called a vapour control layer (VCL) in the UK and often a vapour barrier, is a membrane or coating with low permeability to water vapour. In a roof it limits the amount of indoor moisture that diffuses upward into the insulation, where it could condense on the cold underside of the membrane, wetting insulation, corroding fasteners and degrading adhesives.

Structural deckVapour control layerInsulationCover boardWaterproof membrane Hot-air welding fuses overlapping sheets into one continuous skin
Inside a flat roof

Classes

North American practice groups retarders by permeance measured to ASTM E96:

  • Class I: 0.1 US perm or less (about 5.7 SI perm or less), such as polyethylene sheet, sheet metal, rubber membranes and bitumen membranes
  • Class II: 0.1-1 perm
  • Class III: 1-10 perm
  • Permeable: over 10 perm

Roof materials used

  • self-adhered or torched modified bitumen sheets
  • hot-applied asphalt with felts on concrete decks
  • polyethylene or reinforced foil-faced sheets
  • aluminium-faced bitumen VCLs common in Europe

Where they are needed

Need depends on climate, indoor humidity and the roof type. In heating-dominated climates the retarder goes on the interior side of the insulation; in hot, humid climates exterior vapour drive matters more. Buildings with high indoor humidity such as pools, laundries and food plants usually need robust retarders. In the UK, BS 6229 refers to BS 5250 for condensation risk analysis and uses an external temperature of minus 5 C over 60 days of the heating season.

Vapour retarders and air barriers

A vapour retarder slows diffusion; an air barrier stops air leakage. Air movement carries far more moisture than diffusion, so on roofs, especially mechanically attached roofs over steel decks, the retarder layer is often designed and sealed to act as an air barrier too. Inverted roofs place the membrane itself on the warm side, so it serves this function.

Sources

Reviewed 2 November 2026 · 4 sources · Editorial policy · Plain-text version · Suggest a correction

  1. Vapor barrierWikipedia · en.wikipedia.org
  2. Fit for Mod-BitRoofing Contractor / ARMA · roofingcontractor.com

From the community

Know this topic first-hand? Share a photo you took, a correction with a source, or local knowledge. Every contribution is reviewed before it appears.

Contribute to Vapour Retarder (Vapour Control Layer)

Sign in with your email. We'll send a one-time link; no password needed.