Low-Slope Roof Insulation

Also known as roof insulation · rigid roof insulation · above-deck insulation

Rigid board or sprayed insulation laid above the deck of a low-slope roof, chosen for long-term thermal value, strength, fire and moisture behaviour.

1 min read6 sourcesGlobal
Cite this entry"Low-Slope Roof Insulation." roof.wiki. https://roof.wiki/roof-insulation/ (accessed 2026-11-02).
Common boards
Polyiso, EPS, XPS, mineral wool, cellular glass
Long-term rating (N. America)
LTTR for polyiso and spray foam
UK limit at any point (BS 6229:2025)
U = 0.35 W/m2K
Inverted roof board
Usually XPS

Insulation on low-slope roofs is usually placed above the structural deck as continuous rigid boards, so it insulates without thermal bridging through framing. In a conventional (warm) roof the insulation sits below the membrane; in a protected membrane (inverted) roof it sits above it. Spray polyurethane foam combines insulation and roof substrate in one layer.

Structural deckVapour control layerInsulationCover boardWaterproof membrane Hot-air welding fuses overlapping sheets into one continuous skin
Inside a flat roof

Main materials

  • Polyisocyanurate (polyiso, PIR): the most common North American roof board; high thermal resistance per thickness, foil or fibre-glass facers.
  • Expanded polystyrene (EPS): economical, available in many densities and as tapered boards.
  • Extruded polystyrene (XPS): low water absorption; the standard inverted-roof board.
  • Mineral (stone) wool: non-combustible, dense boards used where fire performance or acoustics matter.
  • Cellular glass: rigid, vapour-tight, high compressive strength; used under heavy loads and in buried roofs.
  • Wood fibre, perlite and phenolic boards in some markets.

Thermal performance and LTTR

Insulation performance is stated as R-value (imperial) or thermal conductivity, lambda, in W/(m.K), and RSI or U-value in metric. Some foams lose thermal resistance as blowing gases diffuse out and air diffuses in, so North America uses long-term thermal resistance (LTTR), a time-weighted value intended to reflect performance over years of service, for polyiso and spray foam. Medium-density closed-cell spray foam has LTTR values of roughly R-5 to R-6 per inch.

Selection factors

  • thermal value and its long-term stability
  • compressive strength under traffic, equipment and ballast
  • moisture tolerance (crucial for inverted and green roofs)
  • fire classification of the assembly
  • compatibility with the membrane and adhesives
  • dimensional stability and ability to be tapered

Codes

Energy codes set minimum roof R-values or U-values; in the UK, BS 6229 references a maximum U-value of 0.35 W/m2K at any point on a heated roof, including low points of tapered schemes. Insulation also forms part of wind-uplift and fire-rated assemblies, so boards, fasteners and adhesives must match tested systems.

Sources

Reviewed 2 November 2026 · 6 sources · Editorial policy · Plain-text version · Suggest a correction

  1. PolyisocyanurateWikipedia · en.wikipedia.org
  2. PolystyreneWikipedia · en.wikipedia.org
  3. Mineral woolWikipedia · en.wikipedia.org
  4. Foam glassWikipedia · en.wikipedia.org
  5. Spray foamWikipedia · en.wikipedia.org

From the community

Know this topic first-hand? Share a photo you took, a correction with a source, or local knowledge. Every contribution is reviewed before it appears.

Contribute to Low-Slope Roof Insulation

Sign in with your email. We'll send a one-time link; no password needed.