Thermal Movement in Metal Roofs

Also known as thermal expansion metal roof · expansion and contraction · thermal cycling

Metal roof panels lengthen and shorten with temperature; systems must let them slide, or seams, fasteners and flashings will fatigue, buckle or leak.

1 min read6 sourcesGlobal
Cite this entry"Thermal Movement in Metal Roofs." roof.wiki. https://roof.wiki/thermal-movement-in-metal-roofs/ (accessed 2026-11-02).
Aluminium vs steel
Aluminium moves about twice as much
Zinc rule of thumb
About 1 in per 30 ft (25 mm per 9 m)
Standing seam solution
Fixed zone plus sliding clips

All metals expand when heated and contract when cooled. A metal roof can swing from below freezing at night to well above air temperature in sun, so a long panel changes length noticeably every day. Good metal roof design does not try to stop this movement; it controls where it happens.

How much metals move

Approximate coefficients of linear expansion:

Metal per degree C (x 10^-6) per degree F (x 10^-6)
Carbon steel 10.8-12.5 6.0-6.9
Copper 16-16.7 8.9-9.3
Stainless steel 304 17.3 9.6
Aluminium 23 12.8
Lead 29 16.1
Zinc 30-35 16.7-19.4

As a worked example, a 10 m (33 ft) aluminium panel warming by 50 degrees C (90 degrees F) grows by about 11.5 mm (0.45 in). One zinc producer's rule of thumb is about 1 in per 30 ft of panel. Aluminium moves roughly twice as much as steel.

Design responses

  • Clips: standing seam panels use a fixed zone (often at the ridge or mid-slope) and sliding or expansion clips elsewhere, so the panel can move away from the fixed point. Sliding clips matter most on long panels and on aluminium; nail-strip (fastening flange) panels restrict movement and are limited to shorter lengths.
  • Slip sheets: on copper and other seamed roofs, rosin paper stops heat-softened asphalt underlayment from bonding the metal to the deck.
  • Bay and pan limits: lead, zinc and soldered flat seam copper are laid in limited bay sizes or with expansion battens and drips.
  • Fasteners: through-fastened sheets must not be overtightened; repeated cycling can loosen or snap screws.
  • Flashings: trims at eaves, ridges and walls must not lock panels at both ends.

Symptoms of restrained movement

Waviness that comes and goes with temperature, popping or ticking noises, elongated fastener holes, broken clips, cracked solder joints and torn seams all suggest that movement has been restrained.

Sources

  1. Coefficients of Linear Thermal ExpansionThe Engineering ToolBox · engineeringtoolbox.com
  2. Essential Zinc: Building for the FutureContinuing Education Center (BNP Media) / Umicore Building Products · continuingeducation.bnpmedia.com
  3. 8.1. Special Roofing Design and Installation ConsiderationsCopper Development Association · copper.org
  4. Metal roofWikipedia · en.wikipedia.org
  5. Thermal Expansion & Oil Canning in Aluminum Roofs ExplainedInterlock Roofing · interlockroofing.com
  6. Standing Seam Types: Snap-Lock vs Mechanical Seam ExplainedInterlock Roofing · interlockroofing.com