Mechanically Attached Roof System

Also known as mechanically fastened roof · mechanically fixed single ply · MA system

A low-slope roof in which the membrane is secured to the deck with screws and plates or bars, typically placed in the sheet laps.

1 min read5 sourcesGlobal
Cite this entry"Mechanically Attached Roof System." roof.wiki. https://roof.wiki/mechanically-attached-roof-system/ (accessed 2026-11-02).
Fastener location
Usually in sheet laps
Common membranes
TPO, PVC, EPDM, modified bitumen base sheets
Field fastener test
ANSI/SPRI FX-1
Known issue
Membrane billowing in wind

In a mechanically attached roof system, the membrane is held down by fasteners driven through it into the structural deck. Most often the fasteners and plates (or continuous metal bars) are placed in the overlap of each seam, so the next sheet covers them and the seam is welded or taped over the top.

Structural deckVapour control layerInsulationCover boardWaterproof membrane Hot-air welding fuses overlapping sheets into one continuous skin
Inside a flat roof

Variations

  • In-seam (lap) fastening: fasteners along one edge of each sheet, covered by the next sheet's lap. This is the most common method for TPO.
  • Strip or bar attachment: continuous bars in or over the seams, or across the field with cover strips.
  • Point attachment: individual plates through the sheet with cover patches.
  • Induction welding: coated plates under the membrane, bonded by induction heat, with no penetrations.

Insulation is usually fastened separately with its own screws and plates, or held by the same fasteners.

Wind design

Fastener spacing and sheet width are set by wind-uplift calculations. Because suction is highest at roof corners and perimeters, these zones use narrower half-sheets or closer fastener spacing. In North America assemblies are tested and listed by FM Approvals and UL, and fastener pull-out strength in existing decks can be checked with the ANSI/SPRI FX-1 field test.

Advantages and limitations

Mechanical attachment is fast, lightweight, works in cold weather when adhesives struggle, and suits steel decks. Its drawbacks include "billowing", where wind lifts the sheet between fastener rows and draws interior air into the roof, possible fastener back-out, and the need for a deck with adequate pull-out strength. Steel deck must be thick enough to hold screws, and some concrete or gypsum decks need special fasteners.

Sources

Reviewed 2 November 2026 · 5 sources · Editorial policy · Plain-text version · Suggest a correction

  1. Cool RoofsU.S. Department of Energy · energy.gov
  2. StandardsSPRI · spri.org

From the community

Know this topic first-hand? Share a photo you took, a correction with a source, or local knowledge. Every contribution is reviewed before it appears.

Contribute to Mechanically Attached Roof System

Sign in with your email. We'll send a one-time link; no password needed.