Quick answers
- What is Fibreglass Shingle?
- An asphalt shingle built on a glass-fibre mat; the dominant form of asphalt shingle sold today.
- What fire rating does Fibreglass Shingle have?
- Up to Class A
- Which standards apply to Fibreglass Shingle?
- ASTM D3462 (min. 1,700 g tear strength)
A fibreglass shingle (US spelling: fiberglass) is an asphalt shingle whose reinforcing core is a non-woven mat of glass fibres bonded with resin, usually urea-formaldehyde. The mat is coated with asphalt that contains powdered mineral filler, then surfaced with granules. Almost all asphalt shingles made today are of this type.
History
Glass-fibre mats were introduced in 1960 with limited success at first. Improvements in mat and coating technology followed, and by about 1982 fibreglass shingles had overtaken organic-felt shingles in the United States. By 2011 organic shingles had disappeared from North American production.
Properties
- Lighter: the glass mat needs less asphalt, so area weights are typically about 1.8-2.3 lb/sq ft (8.8-11.2 kg/m²).
- Fire resistance: glass-mat shingles can achieve a Class A fire rating under ASTM E108 / UL 790, the highest class.
- Moisture: the glass mat does not absorb water, so the shingle is less prone to rot-related curling.
- Brittleness: early products could crack in cold weather or during handling; polymer-modified asphalts were later introduced to improve flexibility.
Standards
In the United States, ASTM D3462 is the main product standard for glass-felt asphalt shingles surfaced with mineral granules, and the International Building Code requires asphalt shingles to comply with it. The standard sets a minimum Elmendorf tear strength of 1,700 g. In Canada, CSA standards apply, and in Europe glass-fibre bitumen shingles are covered by the European harmonised standard for bitumen shingles.
Quality
Weight alone is no longer a reliable sign of quality. Industry commentary notes that mat strength and coating quality vary between products, and a moderate-weight shingle with a strong mat can outperform a heavier one with a weak mat.
On the timeline
- 1700The standard sets a minimum Elmendorf tear strength of 1,700 g.
- 1960Glass-fibre mats were introduced in 1960 with limited success at first.
- c. 1982Improvements in mat and coating technology followed, and by about 1982 fibreglass shingles had overtaken organic-felt shingles in the United States.
Sources
Reviewed 2 November 2026 · 3 sources · Editorial policy · Plain-text version · Suggest a correction
- Asphalt shingleWikipedia · en.wikipedia.org
- Q&A: Fiberglass vs. Organic ShinglesJournal of Light Construction · jlconline.com
- Asphalt Shingle Types (3-Tab vs. Laminated Architectural), ASTM Classifications & Thermal BehaviorOpen Exam Prep · open-exam-prep.com